We improve implantology
for our customers and their patients.
Biological: The design of the implants, the choice of materials, the manufacturing quality and the instruments will be designed according to the state of knowledge of dentistry.
Reliable: The design of the implants and instruments has the goal to enable reliable treatment even in border indications.
Economical: FairImplant aim to provide patients and practitioners with a cost-effective solution to their needs.
Fair: We work in partnership with our customers, suppliers and authorities.
Beginning
FairImplant was founded on the initiative of speakers and participants of periodontological and implantological study groups because they were not fully satisfied with any implant system.
Milestones
around 2000 dentists with a focus on practical education wish for an improved implant system
2005 Foundation – with General Manager Daniel Fraga and Dr. Yves Ospiri
2005 first clinical implementation FairOne
2006 Market entry FairOne
2007 first delivery outside Germany
2008 Start of clinical studies FairWhite
2009 Market entry FairTwo
2011 New General Manager Dipl.-Ing. Jörn Thurow
2011 Implant study at the University of Cologne: FairImplant with top manufacturing quality
2013 first Scanbody FairTwo in 2013
2014 Market entry FairWhite
2015 FairOne 10-year anniversary of clinical use at Hamburg
2015 BDIZ EDI Implant Study: FairImplant with precise production, free of organic residues and residues from the manufacturing process
2016 individual CAM abutment design FairTwo
2017 initiative digital workflow
2020 FairWhite 2.0 – improved strength, higher primary stability, new design parallel
Fitting to the indication
Single-phase or two-phase - titanium or zirconium - each implant has special advantages. The implant types have in common the design according to the IBIC concept and the high production quality.
IBIC Initial Bone to Implant concept
According to the IBIC concept, there is a minimum stability after insertion with decreasing primary stability and incomplete osseointegration. This is associated with an increased failure rate.
All implants of FairImplant are designed in such a way that they achieve very high primary stability from the given situation through shape and implant bed preparation. The precise drill tuning minimizes the distance to the bone and consequently also the duration of osseointegration. The Bonit® coating on titanium implants also accelerates osseointegration.
Manufacture
All implants are manufactured in Germany or Switzerland to the highest quality standards.
Primary stable shape
The root shape of the apex ensures a high degree of stability. This is particularly useful in the case of unfavourable bone conditions.
Biological width / no microgap
The lack of a microgap cannot shelter bacteria, nor is it the starting point for the biological width.
Gentle to soft tissue
The tissue grows firmly on the implant. The prosthetic head have a special roughness for a good attachment.
Matching the bone situation
No bone is a plane. The parallel zone of FairOne makes it possible to compensate for differences in bone height.
Accelerated osseointegration due BONIT®
All titanium implants have a shear-resistant, completely resorbable calcium phosphate coating (BONIT®). The coating has been proven to accelerate the healing process, ensuring successful healing.
• 2-phase CaP coating on all implants
• — Excellent biocompatibility
• — Outstanding hydrophilic properties
• — Layer thickness approx. 20 μm
• On the medical market since 1995
single-phase treatment
Single-phase treatment saves the patient time and money.
Preparable head
The head is preparable. For example, undercuts in the prosthetic restoration can be easily removed.
Prosthetics like tooth stump
Impression-taking and prosthetic restoration correspond to the tooth stump. In contrast to tooth stumps, there are no undercuts, so that cement residues can be safely controlled.
Economical
Single-phase treatment saves the patient time and money.
Primary stable shape
The root shape of the apex ensures a high degree of stability. This is particularly useful in the case of unfavourable bone conditions.
Biological width / no microgap
Platformswitching considers the biological width.
conical connection
The conical internal connection is "virtually one-piece" with an insignificant microgap.
patented rotation protection
The anti-rotation protection allows easy positioning with low tolerances in the rotation.
insertion abutment
All FairTwo implants have an insertion abutment. It allows easy and safe removal and insertion. It is well suited as a temporary abutment or bite registration post
Accelerated osseointegration due BONIT®
All titanium implants have a shear-resistant, completely resorbable calcium phosphate coating (BONIT®). The coating has been proven to accelerate the healing process, ensuring successful healing.
• 2-phase CaP coating on all implants
• — Excellent biocompatibility
• — Outstanding hydrophilic properties
• — Layer thickness approx. 20 μm
• On the medical market since 1995
prosthetic options
Comprehensive possibilities up to patient individual abutments made of prefabricated blanks (PreForm) or DIM analogues for 3D printing. Support of the digital workflow.
Economical
With the insertion abutment, one-piece abutments and Locator, inexpensive restorations are possible.
FairWhite® 2.0 - Shoulder and Parallel
all features on a view
Primary stable design
The root shape of the apex ensures a high degree of stability. This is particularly useful in the case of unfavourable bone conditions.
Biological width / no microgap
The lack of a microgap cannot shelter bacteria, nor is it the starting point for the biological width.
Gentle to soft tissue
The soft tissue loves the zircon ceramic material. As a result, the tissue grows regularly over the implant shoulder without special measures such as protective caps.
high-strength
The shape of the implant is designed to be ceramic-compatible. Ziraldent® is a milestone in terms of bending strength and ageing resistance. The very complex manufacturing process minimizes losses in strength. The surface is applied without any crack induction.
accelerated osseointegration due ZircaPore®
With the ZircaPore® surface, comparable bone healing is achieved compared to titanium surfaces. The layer is shear-resistant. It is basically possible to unscrew during the operation, e. g. in order to change the implant bed preparation.
single-phase treatment
Single-phase treatment saves the patient time and money.
Preparable head
The head is preparable.
Typical preparations on the head have no significant influence on the overall strength.
Prosthetics like tooth stump
Impression-taking and prosthetic restoration correspond to the tooth stump. In contrast to tooth stumps, there are no undercuts, so that cement residues can be safely controlled.
Economical
Single-phase treatment saves the patient time and money.